SMART Researchers Develop Novel Material to Enable Long-term Ultrasound Monitoring

Researchers have developed IP-BBE-PEG, a dry, rubber-like elastomer that transmits ultrasound efficiently while remaining soft and mechanically strong, without relying on liquid gels or additives
The material's acoustic performance comes from its molecular design, specifically how its polymer chains are structured and connected, addressing a key materials challenge in developing wearable ultrasound imaging for continuous, real-time monitoring
The breakthrough offers a potential path towards more stable and practical ultrasound systems for prolonged monitoring, overcoming the limitations of conventional ultrasound gels that can flow, leak or dry out over time
Singapore, 23 November 2026 - Researchers from the Wearable Imaging for Transforming Elderly Care (WITEC) collaborative research project of the Singapore-MIT Alliance for Research and Technology (SMART), MIT’s research enterprise in Singapore, alongside collaborators from the Massachusetts Institute of Technology (MIT), Nanyang Technological University (NTU Singapore) and the National University of Singapore (NUS), have developed a first-of-its-kind dry elastomer, a rubber-like material, that efficiently transmits ultrasound while remaining soft and mechanically strong, addressing a key materials challenge in developing ultrasound systems for continuous, real-time health monitoring that are wearable and portable.
Unlike many existing wearable health technologies that monitor signals at or near the body's surface, ultrasound can image structures and activity deeper inside the body. However, limited by existing technology, conventional ultrasound systems are not designed to maintain a stable, long-term connection to the body and can typically only be used within a hospital, limiting them to snapshots in time rather than continuous monitoring.
A key challenge is ultrasound coupling, which requires a medium to fill small air gaps between the ultrasound probe and the skin, allowing sound waves to travel efficiently between the probe and the body. Conventional ultrasound gels, made up mostly of water with a small amount of thickening polymer, work well for routine and short scans. However, over prolonged use, they tend to flow, leak or dry out over time, making them poorly suited for prolonged monitoring or situations where handling liquid is impractical. Many existing rubbers and polymer-rich gels weaken ultrasound imaging as they absorb too much sound energy needed to form the ultrasound images.
Overcoming these limitations could allow wearable ultrasound systems to provide long-term imaging for continuous, real-time monitoring and diagnosis of chronic conditions such as hypertension and heart failure. This could give healthcare practitioners ongoing clinical insights, beyond the occasional snapshots provided by periodic examinations, supporting earlier detection, timely intervention and more personalised care, while shifting healthcare from reactive, hospital-based treatments towards preventative monitoring and care in community and home-based settings.
Engineering a new material for ultrasound coupling
To overcome this challenge, there is a need for a material capable of transmitting ultrasound efficiently while remaining dry, soft and mechanically strong - soft enough to conform closely to the skin and accommodate body movement without leaving air gaps that disrupt the sound path, and strong enough to provide the durability needed for prolonged wear. These properties have historically been difficult to achieve together in a single material.

The dry, rubber-like material IP-BBE-PEG is soft and stretchable, yet mechanically strong and can maintain efficient ultrasound transmission—properties that allow it to serve as an effective medium for ultrasound coupling for wearable systems (Credit: SMART WITEC)
In a paper titled "Interpenetrating Bottle-Brush Elastomer for Low-Loss Soft Ultrasonic Interfaces," published in the leading multidisciplinary journal Science, the researchers detailed how they addressed this materials challenge through molecular design. The team engineered a dry elastomer by interlocking two polymer networks, each built from bottle-brush elastomer (IP-BBE) with densely grafted polyethylene glycol (PEG) side chains. The material is named IP-BBE-PEG and its polymer chemistry and chain connectivity allow ultrasound to pass through efficiently, rather than being absorbed.
Despite its softness, IP-BBE-PEG also demonstrated strong mechanical durability. In mechanical tests, it was around 12 times more resistant to fracture than SN-BBE-PEG, a traditional single network bottle-brush elastomer with PEG as a side chain, and withstood at least 10,000 loading cycles under the tested conditions.
Couplants that dry out are a practical problem for long-term use as they lose their coupling capability. The researchers tested how IP-BBE-PEG performs against a common hydrogel material and liquid gel as an ultrasound couplant under dehydration. As the materials dried out over time, IP-BBE-PEG remained usable for imaging even after more than a week, while the hydrogel and liquid gel lost their ability to couple ultrasound within just two days and one day, respectively.
Sweat is another challenge for long-term wear, particularly during movement, as trapped liquid can build up between the couplant and the skin, causing irritation and discomfort. In a separate test simulating sweat exposure involving a 10-minute treadmill exercise, sweat pooled under a conventional silicone elastomer and remained pooled even after 35 minutes of rest, while IP-BBE-PEG absorbed and drew the moisture away effectively. Further tests on skin showed no measurable drop in imaging quality after sweat exposure for IP-BBE-PEG.
Finally, to test real-world performance under motion, researchers used IP-BBE-PEG as the couplant for portable ultrasound imaging of a cyclist's neck artery during a 30-minute cycling session. The material successfully captured clear blood flow signals throughout the ride, including while riding uphill, demonstrating the material’s ability to maintain effective ultrasound coupling during sustained movement.
“Bringing softness, mechanical strength and efficient ultrasound transmission together in a single dry material has been difficult to achieve. Our approach addresses this challenge through polymer chemistry and the way the polymer chains are connected to develop a material with the required properties, without relying on liquid or additives,” said Shu Wang, Postdoctoral Associate at the Department of Mechanical Engineering at MIT, and co-first author of the paper.
“Across our tests, IP-BBE-PEG maintained effective ultrasound coupling across the challenging conditions associated with prolonged, wearable imaging, such as dehydration over time, body movement, and sweat exposure, and was able to provide reliable imaging throughout. Notably, its polymer-rich composition is also compatible with commercially available biomedical adhesives, making it an effective and suitable material that can be easily integrated into existing portable ultrasound systems,” said Runze Li, Postdoctoral Associate at the Department of Mechanical Engineering at MIT, and co-first author of the paper.
Moving forward, the WITEC team will be advancing IP-BBE-PEG toward commercial use by developing scalable and reproducible manufacturing processes, reducing material and fabrication costs, and adapting the material and its processing to the requirements of different products and markets.
“Today, ultrasound gives us powerful insights into what is happening deep inside the body, but largely as snapshots in time. Wearable ultrasound could turn those snapshots into a continuous picture, giving healthcare practitioners new ways to monitor changes over time and intervene earlier. This could be significant for societies with growing ageing populations and for people living with chronic conditions, while helping shift healthcare from reactive, hospital-based treatment towards preventative monitoring and care in community and home settings. Advances in materials like IP-BBE-PEG are an important step towards making that possible,” said Professor Xuanhe Zhao, Co-Lead Principal Investigator at WITEC, Professor of Mechanical Engineering and Professor of Civil and Environmental Engineering at MIT, and corresponding author of the paper.
The research conducted at SMART is supported by the National Research Foundation (NRF) Singapore under its Campus for Research Excellence and Technological Enterprise (CREATE) programme.




Comments